Performance Tags Configuration

 

The Performance Tags are predefined formatted tags calculated from Raw Tags. The SNMP FronEnd can automatically detect all needed Raw Tags and configure them for you. All Performance Tags are calculated in server, with wraparound protection, being unnecessary client configuration. All suported tags are listed below:

 

bullet Interface Broadcast Rate: Percentual number of sent and received broadcast packets. It is a ratio calculated using Interface Packet Rate tag.

 

bullet Interface Data Rate: Total traffic data number in bytes. This tag is computed using the total sent and received packets from this interface.

 

bullet Interface Efectiveness: Percentual volume packets discarded because of errors. Indicates the ratio between discarded packets and Interface Packet Rate.

 

bullet Interface Health: A percentual variable calculated using Interface Broadcast Rate, Interface Link Status and Interface Efectiveness. Each of these tags has an adjust, allowing you to make the best configuration. Then, health is computed multiplying all source tags, allowing a unique tag to zero the health.

 

bullet Interface Link Status: Indicates the status of the interface. 0 indicates that this interface is inactive while 1 indicates that is active.

 

bullet Interface Packet Rate: Total number of sent and received packets in this interface.

 

bullet Interface Unicast Rate: Percentual volume of unicast packets. Ratio between sent and received unicast packets and Interface Packet Rate tag.

 

bullet Interface Usage: Interface percentual utilization. Computed using the interface speed and total communication (input/output)in bytes.

 

 

SNMP_Only_ServerConf_PerformanceTags

The Performance Tag List

 

 

There are five columns in Performance Tags list:
 

bullet Enable: Indicates if the server scan is active for current tag.

 

bullet History: Add this tag into XRatel Historian Service.

 

bullet Tag Name: Shows defined tag name for current tag.

 

bullet Tag Type: Informs the type of the tag.

 

bullet Tag Description: An explain text for the tag.

 

The Tag Properties dialog for Performance Tags allows you to configure a tag. Tag Name and Tag Description fields described above can be changed here.

Health tag field activates the inclusion of this tag in device health calculation. This field is available only for Interface Health's tags.

 

 

SNMP_ServerConf_performanceproperties

The Performance Tag Properties Dialog

 

       

                                                                                                                       
 